Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support
                          Heribert

                          Heribert Colombo

                          3

                          Article
                          Last Month

                          -66.67%

                          Heribert articles

                          All Categories
                          • All Categories
                          • Installation
                          • Troubleshooting
                          • Errors & Solutions
                          • License Management
                          • Info
                          • Remote Solve Manager

                          ERROR - Shared Web license shows 0 In use and 0 Available in Ansys Licensing Settings

                          Published October 12th, 2026 by Heribert Colombo

                          ERROR On a machine using Ansys Shared Web Licensing, users can't check out a license (for example, Ansys Mechanical Enterprise). In Ansys Licensing Settings → Products/Shared → On demand, the product's row shows: In use: 0 Available: 0 Software & Version Ansys Shared Web Licensing with Ansys Licensing Settings 2024 R1 and later Any Shared Web pr

                          91 Views 1 min

                          ERROR - Access is Denied When Launching Fluent from Workbench on Remote Linux Nodes

                          Published October 25th, 2026 by Heribert Colombo

                          ERROR When you launch Fluent from Ansys Workbench with Use Remote Linux Nodes enabled, Fluent fails to start Node 0 on the remote Linux system and shows the error below. You cannot run the simulation. Connected License Server List: 1055@xxxxxxxx Host spawning Node 0 on Machine "xxx.xxx.xxx.xx" (lnamd64). Host waiting for connection from Node 0 at "x

                          47 Views 2 min

                          HOW TO - Grant Users Access to Ansys Cloud Burst Compute

                          Published July 3rd, 2026 by Heribert Colombo

                          Overview Before users can submit simulations using Ansys Cloud Burst Compute, an Ansys Support Coordinator (ASC) or Administrator must configure the organization's Ansys Cloud subscription, assign user access, and ensure the required network connectivity is available. This article describes the administrator tasks required to enable Ansys Cloud

                          478 Views 1 min

                          ERROR - Gather Diagnostic Information Fails with NoClassDefFoundError CountingOutputStream on Linux

                          Published November 10th, 2026 by Heribert Colombo

                          ERROR On a Linux license server, gathering diagnostic information fails in both the License Management Center web interface and the gatherdiagnostics command-line script. Clicking Gather Diagnostic Information in License Management Center (http://localhost:1084/ANSYSLMCenter.html) never completes, and you cannot save anything. Running gatherdiagnost

                          25 Views 1 min

                          HOW TO - Install the Ansys License Manager on Linux Without a GUI (Silent Install)

                          Published October 20th, 2026 by Heribert Colombo

                          Description Use this article to install and start the Ansys License Manager (FlexNet) on a Linux server with no graphical user interface (GUI), such as a minimal Ubuntu 24.04 server or one you manage only over SSH (Secure Shell). The default installer opens a graphical window and needs a display, so on a headless server you run it from the command l

                          47 Views 1 min

                          ERROR - Shared Web Licensing Fails with Curl Error 60

                          Published June 3rd, 2026 by Heribert Colombo

                          ERROR When launching an Ansys application with Shared Web Licensing (Ansys hosted entitlement), the following error may appear:   Web Licensing checkout call to Direct LaaS REST API for 1 tasks failed. Error Detail: Curl error 60 encountered on call to https://laas.ansys.com/v1/products/checkout?auto=ordered&format=signed&verbose=true: schan

                          598 Views 1 min

                          ERROR - TD_Welcome is not responding (Thermal Desktop)

                          Published April 14th, 2026 by Heribert Colombo

                          ERROR When launching AutoCAD 2024 with Thermal Desktop installed, AutoCAD opens normally and Thermal Desktop appears available.  However, the AutoCAD becomes unresponsive or crashes when using Thermal Desktop, including: Launching AutoCAD through the Thermal Desktop Launcher (for example, when running the Beer Can tutorial) Running any Thermal Deskt

                          754 Views 1 min

                          ERROR - AEDT Unable to Open Legacy ACIS Geometry Projects in 2025 R1 and Later

                          Published June 2nd, 2026 by Heribert Colombo

                          ERROR When opening a legacy HFSS or AEDT project in Ansys Electronics Desktop (AEDT) 2025 R1 or later, the following message may appear "...was created with ACIS geometry kernel. It cannot be accessed by Electronics Desktop version 2025 R1 and beyond. Please use 2024 R2 version to translate into Parasolid." Software & Version Ansys Electronics D

                          867 Views 1 min

                          HOW TO - Submit a Lumerical FDTD Simulation Using Ansys Cloud Burst Compute

                          Published July 3rd, 2026 by Heribert Colombo

                          Overview Ansys Cloud Burst Compute allows Lumerical FDTD users to run simulations on Ansys-managed cloud hardware without requiring local HPC resources. This article explains how to submit and monitor Cloud Burst Compute jobs from the Lumerical FDTD interface. Validate Prerequisites Before submitting a simulation, verify that: You are using Ansys Lu

                          523 Views 1 min

                          ERROR - EVP_DecryptInit. Could not load the shared library opening Fluent

                          Published March 5th, 2026 by Heribert Colombo

                            ERROR Fluent automatically closes after pressing Start in the Fluent Launcher.   Software & Version Fluent 2025R2 *This documented instance of this error occurred in this version but is not necessarily limited to this version. Description After clicking Start in the Ansys Fluent Launcher, Fluent begins loading but closes immediately. The error

                          11727 Views 1 min
                          Load More

                          Heribert follows these articles

                          • HOW TO - Edit the Windows Hosts File
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! 👋

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted