Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support

                          Installation & Licensing Center

                          • Home
                          • Installation
                            Installation Guides Installation Tasks Requirements & Info Optional Configurations Uninstallation
                          • Troubleshooting
                            Troubleshooting Guides License Manager Connectivity Issues License Checkout Issues Application Functionality Issues Windows OS / Hardware Issues CAD Plugin Issues Project Specific Issues Uninstallation Guides Diagnostic Resources & Logs Other Tasks
                          • Errors & Solutions
                            Behavior Based Issues & Solutions Error Messages & Solutions
                          • License Management
                            FlexNet Licensing Shared Web Licensing Elastic Licensing Licensing Portal Administration License Borrowing Reporting & Usage Stats Other
                          • Info
                          • Remote Solve Manager
                          + More

                          HOW TO - Add FlexNet License Manager Support for Older Ansys Versions (2020 R2 & Prior)

                          Authored by Caleb Scharf October 27th, 2026 8911 views 3 likes KB2702707

                          Description

                          FlexNet License Manager 2024 R1 and later doesn't support Ansys clients 2020 R2 and prior, unless you upgraded it from License Manager 2023 R2 or prior. Upgrading means installing a new version on top of the old one.

                          These older clients need the Ansys License Interconnect service on port 2325. A new 2024 R1 or later install doesn't include that service, because Ansys is retiring it: clients 2021 R1 and later don't use it. This article shows license server administrators how to check for support and add it.

                          Solution

                          1. Check Whether Your License Manager Supports Older Clients

                          Skip to Add Support for Older Clients if you don't have the License Manager installed yet.

                          1. Search Windows for Ansys License Management Center, right-click it, and select Run as administrator.

                          2. In the License Management Center, check whether the license server status lists the Ansys License Interconnect as running.

                          3. Decide what to do next:
                            • If the Ansys License Interconnect is running: your License Manager already supports clients 2020 R2 and prior. You don't need to change anything.
                            • If the Ansys License Interconnect isn't listed or isn't running: follow Add Support for Older Clients below.

                          2. Add Support for Older Clients

                          Uninstall Before You Downgrade

                          Installing an older License Manager over a newer one causes errors. To downgrade the License Manager, always uninstall the current version first. You don't need to uninstall to upgrade.

                          1. Uninstall your current License Manager. See HOW TO - Uninstall Ansys Software.

                            Important: Skip to step 3 unless you have License Manager 2024 R1 or later that you didn't upgrade from 2023 R2 or prior.

                            Important: Skip to step 4 if you have License Manager 2023 R2 or prior installed. To find your version, see HOW TO - Check Ansys License Server Version.
                          2. Rename the C:\Program Files\ANSYS Inc\Shared Files folder to Shared Files.old. A clean folder lets the new install succeed.
                          3. Install License Manager 2023 R2 or prior. Follow the Ansys Download & Installation Guide (Start Here!).
                          4. Install the latest version of the License Manager, using the same Ansys Download & Installation Guide (Start Here!).

                            Note: This upgrades your installation; it doesn't install a second copy.

                          3. Verify It Worked

                          1. Open the Ansys License Management Center again and check that the Ansys License Interconnect is running.
                          2. Open your Ansys 2020 R2 or prior client and check that it gets a license. If it does, you're done.

                          Note: If the client can't get a license, see HOW TO - Test & Fix FlexNet License Manager Connectivity Issues.

                          enable older

                          Was this helpful?

                          Yes
                          No

                          3 out of 3 found it helpful

                          Related Articles

                          HOW TO - Make an Ansys License Server Public Facing (BYOL)

                          HOW TO - Set User License Privileges via an Options File

                          HOW TO - Enable the Ansys Idle Timeout Feature

                          HOW TO - Create an ansyslmd.opt OPTIONS file

                          Popular Articles

                          Ansys Download & Installation Guide

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          HOW TO - Uninstall Ansys Software

                          HOW TO - Test & Fix FlexNet License Manager Connectivity Issues

                          HOW TO - Install an Ansys FlexNet License Key/File

                          Was this helpful?

                          Yes
                          No
                          Give feedback about this article

                          Can't find what you're looking for?

                          Contact Support

                          Recently Updated

                          • ERROR - The application requires the use of OpenGL version 4.3 (Ansys Mechanical)
                          • HOW TO - Install Ansys MCP Servers (VS Code & GitHub Copilot)
                          • HOW TO - Run Product & CAD Configuration Manager
                          • ERROR - Gather Diagnostic Information Fails with NoClassDefFoundError CountingOutputStream on Linux
                          • HOW TO - Download the Ansys Electronics Package (HFSS, Maxwell, Icepak, SIwave, Nuhertz)
                          • INFO - Ansys Hardware Recommendations & Supported 3rd Party Software
                          • HOW TO - Obtain Usage Data for Usage Reporting
                          • HOW TO - Fix Ansys Installation / Functionality Issues
                          • HOW TO - Edit the Windows Hosts File
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! đź‘‹

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted