Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support

                          Installation & Licensing Center

                          • Home
                          • Installation
                            Installation Guides Installation Tasks Requirements & Info Optional Configurations Uninstallation
                          • Troubleshooting
                            Troubleshooting Guides License Manager Connectivity Issues License Checkout Issues Application Functionality Issues Windows OS / Hardware Issues CAD Plugin Issues Project Specific Issues Uninstallation Guides Diagnostic Resources & Logs Other Tasks
                          • Errors & Solutions
                            Behavior Based Issues & Solutions Error Messages & Solutions
                          • License Management
                            FlexNet Licensing Shared Web Licensing Elastic Licensing Licensing Portal Administration License Borrowing Reporting & Usage Stats Other
                          • Info
                          • Remote Solve Manager
                          + More

                          ERROR - Fluent Crashes Intermittently or Graphics Window Is Blank (HOOPS_PICTURE)

                          Authored by Carlos Rodriguez October 12th, 2026 6 views 0 likes KB3972514

                          ERROR

                          Fluent closes unexpectedly (aborts) at random points during a session on Windows. The crash is intermittent and can go several sessions without happening.

                          After the graphics driver is changed to stop the crash, graphics windows (mesh, contours, plots) may open but stay solid gray with nothing drawn.

                          If the graphics driver variable is misspelled, the Fluent console shows the following at startup and falls back to DirectX 11:

                          Graphics driver currently in use: dx11
                          Warning:
                          Specified graphics driver "opengi2" is not available on the current runtime environment.
                          Selected dx11 instead, the most appropriate driver for it.

                          Software & Version

                          Fluent 2026 R1 on Windows 11. 

                          Description/Cause

                          Fluent supports several graphics drivers, and the best one depends on the machine's graphics hardware. On this system, the intermittent crash was tied to the DirectX 11 (dx11) driver. The HOOPS_PICTURE system environment variable sets which driver Fluent uses. Setting it to OpenGL2 stopped the crash but left the graphics window blank. A software-rendered driver brought the display back.

                          Solution

                          1. Close all Ansys applications.
                          2. Open the Windows Start menu, search for Edit the system environment variables, and open it. Administrator rights are required.
                          3. Click Environment Variables.
                          4. Under System variables, click New and create:
                          • Variable name: HOOPS_PICTURE
                          • Variable value: opengl2

                          Type the value in lowercase. The character after "openg" is a lowercase L, not a capital I.

                          1. Click OK to save, then restart the machine.
                          2. Launch Fluent and check the console. If it shows the "Specified graphics driver ... is not available" warning, the value is misspelled. Correct it and restart.
                          3. Load a case and display a mesh or contour. If the graphics window shows it, you do not need to change anything else.
                          4. If the graphics window stays solid gray, edit HOOPS_PICTURE, change the value to opengl2-mesa, restart the machine, and test again.
                          5. If the display is still blank, change the value to msw, restart the machine, and test again.
                          6. If none of these values restores the display, update the graphics card driver from the manufacturer's website. See ERROR - Cannot See Model in Graphics Area.

                          Note: opengl2-mesa and msw draw graphics in software, so the display can update more slowly on large models.

                          Was this helpful?

                          Yes
                          No

                          0 out of 0 found it helpful

                          Related Articles

                          ERROR - Fluent fails to open or crashes frequently

                          ERROR - Graphics Disappear when using Selection Mode

                          ERROR - Application failed to Start due to Qt Platform plugin

                          Popular Articles

                          Ansys Download & Installation Guide (Start Here!)

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          HOW TO - Uninstall Ansys Software

                          HOW TO - Test & Fix FlexNet License Manager Connectivity Issues

                          HOW TO - Install an Ansys FlexNet License Key/File

                          Was this helpful?

                          Yes
                          No
                          Give feedback about this article

                          Can't find what you're looking for?

                          Contact Support

                          Recently Updated

                          • HOW TO - Download the Ansys Structures Package (Mechanical, Mechanical APDL, Autodyn, LS-DYNA)
                          • ERROR - No Shared Web license found that enables feature aice_pak (Icepak Classic)
                          • ERROR - Fluent Crashes Intermittently or Graphics Window Is Blank (HOOPS_PICTURE)
                          • HOW TO - Download the Ansys Electronics Package (HFSS, Maxwell, Icepak, SIwave, Nuhertz)
                          • HOW TO - Remove the User ansyslmd.ini Configuration File
                          • HOW TO - Change/Rehost a FlexNet License Server
                          • HOW TO - Install Granta MI Pro (Automated)
                          • INFO - Ansys Version & Release Date History
                          • HOW TO - View All Your License Entitlements
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! 👋

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted