ERROR - Proxy process identifier could not be determined

Authored by Aaron Schedlin April 12th, 2023 277 views 0 likes KB1898875

ERROR

When submitting a job via RSM you receive an error message.  Example:[2023-04-04 3:56:52 PM]    Submission in progress...    31       |   [2023-04-04 3:56:53 PM]    Proxy process identifier could not be determined. Probably couldn't be started.


 30       |   [2023-04-04 3:56:52 PM]    Submission in progress...    31       |   [2023-04-04 3:56:53 PM]    Proxy process identifier could not be determined. Probably couldn't be started.    32       |   [2023-04-04 3:56:53 PM]    --- System.AggregateException: One or more errors occurred.    33       |   [2023-04-04 3:56:53 PM]       at System.Threading.Tasks.Task.ThrowIfExceptional(Boolean includeTaskCanceledExceptions)    34       |   [2023-04-04 3:56:53 PM]       at System.Threading.Tasks.Task.Wait(Int32 millisecondsTimeout, CancellationToken cancellationToken)    35       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.ManagementUtilities.AbstractAsyncResult`1.WaitOnTaskAndLogExceptions()    36       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.ManagementUtilities.AbstractAsyncResult`1.WaitUntilDone(WaitHandle cancelHandle, TResult& result)    37       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.JobManagement.Core.SubmitAsyncResult.DoUploadUsingStorageManagement()    38       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.JobManagement.Core.SubmitAsyncResult.DoTaskOperation()    39       |   [2023-04-04 3:56:53 PM]    --- System.InvalidOperationException: Proxy process identifier could not be determined. Probably couldn't be started.    40       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.ManagementUtilities.Utilities.GetUserProxyPort(String passwordDestination, String submitHost)    41       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.StorageManagement.StorageUtilities.CreateStorageRequirements(StorageArchitecture arch, String sourceDirectory, ClusterConfiguration clusterConfiguration)    42       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.StorageManagement.StorageCreationAsyncResult.CreateFromLegacyConfig()    43       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.StorageManagement.StorageCreationAsyncResult.CreateForLegacy()    44       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.StorageManagement.StorageCreationAsyncResult.DoTaskOperation()    45       |   [2023-04-04 3:56:53 PM]       at Ansys.Rsm.StorageManagement.AbstractStorageAsyncResult`1.TaskOperation()    46       |   [2023-04-04 3:56:53 PM]       at System.Threading.Tasks.Task`1.InnerInvoke()    47       |   [2023-04-04 3:56:53 PM]       at System.Threading.Tasks.Task.Execute()    48       |   [2023-04-04 3:56:53 PM]    Job submission failed.    49       |   [2023-04-04 3:56:53 PM]    Finalize not required since submission failed or aborted.    50       |   [2023-04-04 3:56:53 PM]    Release request received.

Software & Version

Ansys RSM 2020 R2

*This error was identified in this version but may occur in other versions.


Description/Cause

There is a "zombie" userproxy process running.

*The cause(s) we identified in this documented instance may not be the only cause(s) for this error.

Solution

  1. Please login to the machine running the JobManager (Launcher) service and check for any hung UserProxy (version number) processes for the user. If there are no other completed or active jobs for the user, end the process.
  2. If no zombie processes are running for the user, then stop and start the RSM launcher process on the RSM server after any running jobs have ended. Please alert all end users of the service stop and start so they can avoid submitting jobs until the service is restarted.


mistakeerror

Did you like this article?

Yes
No

0 out of 0 liked this article

Related Articles

ERROR - "Ansys BladeModeler" Not Available When Opening DesignModeler

ERROR - Cannot return a borrowed license

ERROR - No valid INCREMENT lines were found

Popular Articles

INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

Ansys Download & Installation Guide (Start Here!)

Ansys Troubleshooting Guide

ERROR - Hostid in the license file is not a valid hostid

Accessing the Ansys Customer Portal

Did you like this article?

Yes
No
Give feedback about this article

Can't find what you're looking for?

Contact Support

Recently Updated

  • HOW TO - Gather Ansys Diagnostic Logs
  • ERROR - Failover Feature 'Ansys electronics_desktop' is not available
  • ERROR - Switching Network Connections Checks Out Another License
  • Specifying an Ansys License Server
  • ERROR - Cannot Borrow a License
  • HOW TO - Gather License Server Host Info
  • ERROR - Electronics Desktop opens as Twin Builder or another Desktop Configuration
  • ERROR - Request name cfd_solve_level2 does not exist in the licensing pool (-15,10032)
  • HOW TO - Reset Your Ansys Profile Folder

General Inquiries & Sales:

(800) 566-9190

Info@SimuTechGroup.com

Contact Support

  • Software
  • Services
  • Case Studies
  • Ansys Training
  • Consulting
  • Technical Support
  • About SimuTech
  • Careers
  • Privacy

© 2021 SimuTech Group

Definition by Author

0
0
Expand

Thanks for your feedback!

How can we improve this article?

We're glad you liked the article!

What specifically did you like, so we can do that more!

Thanks for your time!

What feedback do you have for us?