Contact Us

If you still have questions and are an active SimuTech customer, please submit a request.

  • Ansys Training
  • Skills Center
  • Consulting
  • About
  • Contact Support
  • Home

  • Installation

      • Troubleshooting

          • Errors & Solutions

              • License Management

                  • Info

                      • Remote Solve Manager

                          • Employee Login

                          Can't find what you're looking for?

                          Contact Support

                          Installation & Licensing Center

                          • Home
                          • Installation
                            Installation Guides Installation Tasks Requirements & Info Optional Configurations Uninstallation
                          • Troubleshooting
                            Troubleshooting Guides License Manager Connectivity Issues License Checkout Issues Application Functionality Issues Windows OS / Hardware Issues CAD Plugin Issues Project Specific Issues Uninstallation Guides Diagnostic Resources & Logs Other Tasks
                          • Errors & Solutions
                            Behavior Based Issues & Solutions Error Messages & Solutions
                          • License Management
                            FlexNet Licensing Shared Web Licensing Elastic Licensing Licensing Portal Administration License Borrowing Reporting & Usage Stats Other
                          • Info
                          • Remote Solve Manager
                          + More

                          HOW TO - Turn Off or Change the Ansys License Expiration Warning

                          Authored by Heribert Colombo November 26th, 2026 2 views 0 likes KB4125739

                          Description

                          Ansys shows a license expiration warning starting 30 days before a license entitlement expires. During a renewal, the expiring and renewed entitlements are separate entries in the license file. The warning only checks the expiring one, so it can appear even after you have renewed.

                          upload-0c2da25f-0.png

                          This article shows administrators how to change or turn off the warning with the ANS_FLEXLM_EXPWARN_DAYS environment variable.

                          Solution

                          1. Check That Your Renewed Licenses Are Installed

                          Before you change the warning, confirm that the warning is not about a license that is really expiring.

                          1. On each FlexNet license server, open the Ansys License Management Center as Administrator. See HOW TO - Open the Ansys License Management Center.
                          2. Click View FlexNet Licenses.
                          3. Find the features named in the warning. Check that each one lists two entries: the current entitlement with its expiration date, and the renewed entitlement starting the next day with its new expiration date.

                            Note: If you only see the current entitlement, install the updated license file first. See HOW TO - Install an Ansys FlexNet License Key/File.

                            Note: To have SimuTech check the license server for you, follow Step 2 of HOW TO - Gather Ansys Diagnostic Logs and send the license server diagnostics to SimuTech support.

                          When both entries are present, the warning is expected. It stops once the renewed entitlement starts.


                           

                          2. Set the Expiration Warning Variable

                          Set It on Every Computer That Runs Ansys

                          The variable works on the client, where Ansys launches, not on the license server. It suppresses warnings only for the user or computer where you set it. To avoid setting it machine by machine, deploy it through your endpoint management system.

                           

                           

                          1. Close all Ansys applications.
                          2. Open the Windows Start menu, search for "Edit the system environment variables", and open it.
                          3. Click Environment Variables.
                          4. Under "System variables", click New, and enter these values:

                          Setting

                          Value

                          Variable name ANS_FLEXLM_EXPWARN_DAYS
                          Variable value 0 (turns off the warning), or 7 to 90 (days before expiration that the warning starts; the default is 30)

                           

                          0 Also Hides Real Expirations

                          A value of 0 also hides warnings for licenses you are not renewing. To keep a short notice instead, use a low value such as 7.

                           

                           

                          1. Click OK in each window to save.

                           

                          3. Verify It Worked

                          1. Launch Ansys on a computer where you set the variable.
                          2. Check that the license expiration warning no longer appears. If you set a value from 7 to 90, the warning appears only that many days before an entitlement expires.
                          3. If the warning still appears, check that the variable name is exactly ANS_FLEXLM_EXPWARN_DAYS and is set on the computer where Ansys launches. Then close and relaunch Ansys.

                           

                          Note: For how entries in a license file work, see INFO - Understanding Ansys License Files (ansyslmd.lic).

                          license expiringexpiration warningans_flexlm_expwarn_daysentitlement renewalflexnet licenseenvironment variablelicense renewal warningturn off warning

                          Was this helpful?

                          Yes
                          No

                          0 out of 0 found it helpful

                          Related Articles

                          INFO - Ansys License Server Commands

                          INFO - Is a Evaluation/Temporary License Borrowable?

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          INFO - Setting up a VPN to an Ansys License Server

                          Popular Articles

                          Ansys Download & Installation Guide

                          INFO - Ansys Hardware Recommendations & Supported 3rd Party Software

                          HOW TO - Uninstall Ansys Software

                          HOW TO - Test & Fix FlexNet License Manager Connectivity Issues

                          HOW TO - Install an Ansys FlexNet License Key/File

                          Was this helpful?

                          Yes
                          No
                          Give feedback about this article

                          Can't find what you're looking for?

                          Contact Support

                          Recently Updated

                          • HOW TO - Add Firewall & Port Exceptions for Ansys License Manager
                          • HOW TO - Turn Off or Change the Ansys License Expiration Warning
                          • HOW TO - Install Ansys MCP Servers (VS Code & GitHub Copilot)
                          • ERROR - The application requires the use of OpenGL version 4.3 (Ansys Mechanical)
                          • HOW TO - Run Product & CAD Configuration Manager
                          • ERROR - Gather Diagnostic Information Fails with NoClassDefFoundError CountingOutputStream on Linux
                          • HOW TO - Download the Ansys Electronics Package (HFSS, Maxwell, Icepak, SIwave, Nuhertz)
                          • INFO - Ansys Hardware Recommendations & Supported 3rd Party Software
                          • HOW TO - Obtain Usage Data for Usage Reporting
                          • General Inquiries & Sales:
                          • (800) 566-9190
                          • Info@SimuTechGroup.com
                          • Contact Support
                          • Software
                          • Services
                          • Case Studies
                          • Ansys Training
                          • Consulting
                          • Technical Support
                          • About SimuTech
                          • Careers
                          • Privacy

                          © 2025 SimuTech Group


                          Knowledge Base Software powered by Helpjuice

                          Definition by Author

                          0
                          0
                          Expand NEW TAB

                          Hi there! 👋

                          How are you liking the Installation Center?

                          Terrible

                          Bad

                          OK

                          Good

                          Excellent

                          Feedback Successfully submitted